Skip to main content

EMC VPLEX Integration ZenPack

Support

This ZenPack is developed and supported by Virtana. Enterprise support is available to Virtana customers with an active subscription or support agreement. ZenPacks are available at delivery.zenoss.com. To request more information about this or any other ZenPack, contact Virtana.

This ZenPack is developed and supported by Virtana Professional Services, and is a supplemental monitoring offering to the standard Virtana product subscription or support agreement. These are offered as separate subscriptions in order to provide initial setup, training, and ongoing compatibility and maintenance. All standard packages are renewable every 12 months from the date of purchase. Contact Virtana to request more information regarding this or any other ZenPacks.

Name:

EMC VPLEX Integration ZenPack

Release:

1.0

About

This ZenPack receives SNMP Traps and transforms them into Virtana Events. Device modeling and monitoring is provided via SNMP and REST API Connectivity.

Limitations

ZenPack is designed to support the following VPLEX device models: Local and Metro version 5.3

Prerequisites

Prerequisite

Restriction

Product

Zenoss 4.2.5 or higher

Required ZenPacks

ZenPacks.zenoss.ZenPackLib >= 2.1.1 ZenPacks.zenoss.PS.Util >= 1.2.0

Other dependencies

None

Features

Device Classes

A new device class /Storage/EMCVPLEX will be added

Configuration properties

Basic device monitoring uses SNMP, for full modeling REST API Credentials must be provided:

  • zEMCVPLEXUsername

  • zEMCVPLEXPassword

  • zEMCVPLEXPort

  • zEMCVPLEXSSL

  • zEMCVPLEXConcurrency

    • The number of concurrent connections allowed to the VPLEX endpoint. (Note: the limit is enforced per-process, so Modeling and Collection may both hit this limit.)

    • Default: 3

Device Monitoring

The following metrics are monitored on the VPLEX Device via SNMP.

  • CPU Idle

  • Heap Used

  • Front End Ports

    • Bytes Read/Write

    • Ops Read/Write

    • Average Read/Write Latency

    • Ops Active

    • Ops Queued

  • Backend Ports

    • Bytes Read/Write

    • Ops Read/Write

Components

  • VPLEX Engine

    • Modeled Attributes

      • family

      • part_number

      • revision_number

      • serial_number

      • wwn_seed

    • Monitoring

      • HealthState

      • OperationalStatus

  • VPLEX Fan

    • Monitoring

      • OperationalStatus

      • SpeedThresholdStatus

  • VPLEX Power Supply

    • Modeled Attributes

      • part_number

      • revision_number

      • serial_number

    • Monitoring

      • OperationalStatus

      • TemperatureThresholdStatus

  • VPLEX Consistency Group

    • Modeled Attributes

      • cache_mode

      • detach_rule

      • recoverpoint_enabled

      • storage_at_cluster

  • VPLEX Storage Volume

    • Modeled Attributes

      • capacity

      • io_status

      • storage_volume_type

      • total_free_space

      • vendor_specific_name

      • storage_array

    • Monitoring

      • OperationalStatus

      • HealthState

  • VPLEX Virtual Volume

    • Modeled Attributes

      • capacity

      • expandable

      • expandable_capacity

      • expansion_method

      • recoverpoint_usage

      • volume_type

  • VPLEX Cluster

    • Modeled Attributes

      • top_level_assembly

      • default_director

    • Monitoring

      • HealthState

      • OperationalStatus

  • VPLEX Extent

    • Modeled Attributes

      • capacity

      • vendor_name

      • storage_volume

      • storage_volume_type

      • system_id

    • Monitoring

      • HealthState

      • OperationalStatus

  • VPLEX Local Device

    • Modeled Attributes

      • capacity

      • expandable_capacity

      • geometry

      • stripe_depth

    • Monitoring

      • HealthState

      • OperationalStatus

  • VPLEX Storage Array

    • Modeled Attributes

      • auto_switch

      • controllers

      • ports

    • Monitoring

      • ConnectivityStatus

  • VPLEXLun

    • Modeled Attributes

      • active_controller

      • alua_support

      • passive_controller

      • visibility

    • Monitoring

      • ConnectivityStatus

Events

This ZenPack uses Transforms to generate the following events from SNMP Traps:

VPLEX Event Code

Severity

Description

0x8a029033

CRITICAL

The on-disk configuration information for the reported device is inconsistent, due to the parent having an invalid type.

0x8a029034

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029035

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029036

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029037

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029038

CRITICAL

The on-disk configuration information for the reported device is inconsistent because a parent device has a blocksize of zero.

0x8a029039

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a02903a

CRITICAL

The on-disk configuration information for the reported device is inconsistent due to inconsistent child and parent node counts.

0x8a02903b

CRITICAL

The on-disk configuration information for the reported device has inconsistent sibling IDs.

0x8a02903c

CRITICAL

The on-disk version configuration information for the reported device is inconsistent.

0x8a02903d

CRITICAL

The on-disk configuration information for the reported device is inconsistent because different child and parent versions were detected.

0x8a02903e

CRITICAL

The on-disk configuration information for the reported device is inconsistent because of an unknown parent type.

0x8a02903f

CRITICAL

The on-disk configuration information for the reported device is inconsistent because the parent's child slot already in use.

0x8a029040

CRITICAL

The on-disk configuration information for the reported device is inconsistent due to the proposed and current child versions.

0x8a029045

CRITICAL

The on-disk configuration information for one of the devices is inconsistent because the child name exceeds the maximum length.

0x8a029046

CRITICAL

The on-disk configuration information for the reported device is inconsistent because there is no noodecount for the parent.

0x8a029047

CRITICAL

The on-disk configuration information for one of the devices is inconsistent because a parent ID has an invalid length.

0x8a029048

CRITICAL

The on-disk configuration information for one of the devices is inconsistent due to the invalid length of the parent type.

0x8a029049

CRITICAL

The on-disk configuration information for one of the devices is inconsistent due to the child node count being exceeded.

0x8a02904b

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a02904c

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a02904d

CRITICAL

Check the status of the devices to determine which device is not available.

0x8a02904e

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a02904f

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029050

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029051

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029052

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029053

CRITICAL

Check the status of the devices to determine which device is not available.

0x8a029054

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029055

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029056

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029057

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029058

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a029059

CRITICAL

The on-disk configuration information for one of the devices is inconsistent.

0x8a02905c

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a029060

CRITICAL

The storage volume has become unreachable.

0x8a029061

CRITICAL

The storage volume has failed, and there is no mirror of the storage volume.

0x8a026062

ERROR

The system lost access to the reported storage volume.

0x8a02606f

ERROR

Two discovered devices reported the same device name.

0x8a029071

CRITICAL

Conflicting device configuration information was found on storage volumes.

0x8a029072

CRITICAL

The given storage volume has problems that prevent VPLEX from reading data on it.

0x8a02907a

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a02907b

CRITICAL

The on-disk configuration information for the reported device is inconsistent.

0x8a02307e

WARNING

The system has lost access to the logging-volume device on which it was maintaining a list of changes to the reported device.

0x8a029089

CRITICAL

VPLEX cannot do the necessary sector reassignment, because the reported storage volume has no mirror.

0x8a02308d

WARNING

If we are currently rebuilding the mirror, we will roll back the write only as far as the block in question.

0x8a029092

CRITICAL

All of the mirrors of the specified distributed device had been marked out of date.

0x8a029093

CRITICAL

A miki-rebuild has failed because I/O that was part of that rebuild has failed to the local child of a distributed RAID-1.

0x8a02609e

ERROR

A storage volume has been provisioned to this cluster, even though the storage volume logically belongs to another cluster.

0x8a0290a2

CRITICAL

The active meta-volume has become unhealthy and is at risk.

0x8a0260b5

ERROR

Manual intervention is required.

0x8a0260be

ERROR

The automatic detach of the given cluster from the given device was disallowed, in order to preserve consistency on the device and avoid losing data.

0x8a0260bf

ERROR

The automatic detach of missing clusters from the given device was disallowed based on majority rules, in order to preserve consistency on the device and avoid losing data.

0x8a0290c5

CRITICAL

A write to the specified metadata volume has failed.

0x8a0290d1

CRITICAL

A conflict has been detected between the views of two or more directors as to which metadata amf should be marked active at a cluster.

0x8a0290dd

CRITICAL

The same disk has been not only presented to multiple clusters, but claimed at those clusters as well.

0x8a0230df

WARNING

A disk in a metadata volume has become unreachable or unhealthy, thereby reducing the redundancy of the metadata volume.

0x8a0230e2

WARNING

A fixed time has passed after the local cluster last booted, and the active metadata volume has not yet been detected.

0x8a0290e5

CRITICAL

Invalid settings were read from the metadata.

0x8a0290e6

CRITICAL

Check the status of the devices to determine which device is not available.

0x8a0290e7

CRITICAL

Check the status of the devices to determine which device is not available.

0x8a0230e9

WARNING

Metavolume is running out of available space.

0x8a0290f4

CRITICAL

All the storage-volume(s) supporting this mirror leg are performing very poorly, causing severe degradation in the RAID-1 performance.

0x8a036010

ERROR

Ensure the spare pools required to support automatic storage volume replacement exist and contain storage volumes.

0x8a0a300b

WARNING

Local directors are running different versions of software.

0x8a0a6018

ERROR

Several wan-com or local-com messages took longer than the allowed round-trip latency in the past hour.

0x8a459010

CRITICAL

An IP network device is no longer present.

0x8a453013

WARNING

Link went down on a port, depending on the port role, a physical path to local or remote cluster has been lost.

0x8a459018

CRITICAL

An SFP is missing, inserted incorrectly, or faulty.

0x8a45901a

CRITICAL

The EMC part number of the SFP was not recognized.

0x8a45901c

CRITICAL

Incoming laser is not detected on an optical Ethernet port.

0x8a45901e

CRITICAL

One 10Gig Ethernet IO module has defective firmware.

0x8a45301f

WARNING

One 10Gig Ethernet IO module has firmware version that is earlier than any validated version.

0x8a453022

WARNING

Attempts to establish the link is failing continuously.

0x8a456027

ERROR

The WAN-COM port is configured with non IPV4 protocol.

0x8a45302e

WARNING

The last redundant IP path to the specified director is down.

0x8a0e901c

CRITICAL

A series of transient errors were detected while trying to read or write the given block range of the given storage volume.

0x8a109002

CRITICAL

During failure recovery, another disruption occurred, and could not be handled.

0x8a113014

WARNING

Recovery from simple director failure took too long.

0x8a183004

WARNING

If the director has halted due to a software error, it will be reset automatically; otherwise, manual intervention will be required.

0x8a18901f

CRITICAL

Either a memory leak has occurred or the VPLEX has exceeded its configuration limits.

0x8a186020

ERROR

An internal environment operation failed.

0x8a266032

ERROR

The last director with the given cluster id has departed.

0x8a269038

CRITICAL

This director is trying to kill the identified director, but the call to do that has failed.

0x8a269039

CRITICAL

An internal call to reset another director has failed.

0x8a266040

ERROR

A director with a different version of firmware may have been inserted into the cluster.

0x8a266041

ERROR

A director with a different version of firmware may have been inserted into the cluster.

0x8a266042

ERROR

A director with a different version of firmware may have been inserted into the cluster.

0x8a266043

ERROR

A director with a different version of firmware may have been inserted into the cluster.

0x8a269045

CRITICAL

The director will be in a partially booted state, which allows a value to be set for director-count.

0x8a266064

ERROR

This failure exposes the cluster to a Data Unavailability condition in certain director failure/inter-director link failure scenarios.

0x8a269069

CRITICAL

The cluster reporting this event has been unable to establish communication with Cluster Witness Server.

0x8a266073

ERROR

Cluster Witness cannot be enabled on systems with more than the supported number of clusters.

0x8a269074

CRITICAL

The cluster reporting this event has been unable to receive any guidance from the Cluster Witness Server for the last 10 seconds.

0x8a266078

ERROR

There are no known causes for this condition.

0x8a276005

ERROR

The non-volatile file system has been corrupted and must be repaired.

0x8a276006

ERROR

The non-volatile file system is either not configured or has been corrupted.

0x8a276007

ERROR

Create a larger meta-volume with a larger NVOL file system.

0x8a276009

ERROR

A write error occurred to the non-volatile storage server and data was not written to disk.

0x8a2d6045

ERROR

The failure is due to the limit on number of steps that can be added was reached.

0x8a2d6046

ERROR

Tried to allocate structure and failed.

0x8a2d6047

ERROR

A logical unit has inconsistent path types.

0x8a2d304f

WARNING

Target device advertised a behavior which is not supported by the VPLEX initiator.

0x8a2d605b

ERROR

LuId already has maximum controllers allowed on this array.

0x8a2d307b

WARNING

A back end Logical Unit has reported an unexpected peripheral qualifier.

0x8a2d307e

WARNING

An inconsistent ALUA support level has been detected for a logical unit.

0x8a2d608A

ERROR

This logical unit is reserved by another initiator.

0x8a2d6093

ERROR

LU mapping on the back-end array had changed.

0x8a2d6094

ERROR

This Initiator-Target connection is failing and is out of service.

0x8a2d309A

WARNING

This logical unit has been busy more often than is considered acceptable

0x8a2d309e

WARNING

The array reported an unexpected serial number.

0x8a04900f

CRITICAL

This is likely indicative of severely degraded hardware and/or fabric condition.

0x8a343017

WARNING

The host application or OS requested an invalid transfer size on a Scsi Compare and Write Command.

0x8a343018

WARNING

The host application or OS specified an out of range Logical Block Address on a Scsi Compare and Write Command.

0x8a346019

ERROR

The VPLEX director had insufficient memory resources to process the Scsi Compare and Write Command.

0x8a34601a

ERROR

The attempt to start a cache transaction for a Scsi Compare and Write command failed.

0x8a34601d

ERROR

The VPLEX director had insufficient memory resources to process the Scsi Write Same Command.

0x8a34301e

WARNING

The attempt to start a cache transaction for a Scsi Write Same command failed.

0x8a34301f

WARNING

Scsi Write Same command processing is disabled on VPLEX.

0x8a346020

ERROR

Host initiator has issued target reset due to slow I/O processing.

0x8a3a9000

CRITICAL

An internal software error has occurred, which may be triggered by unexpected changes in the cluster's environment or configuration.

0x8a3a6010

ERROR

There are already three instances of the given management command currently running, and more than three are not allowed.

0x8a523001

WARNING

A persisted record for a consistency group had a format unrecognized by the system.

0x8a523002

WARNING

A persisted record for a volume set property had a format unrecognized by the system.

0x8a523003

WARNING

A persisted record for a volume set property had a type unrecognized by the system.

0x8a52601d

ERROR

The system disallowed the automatic detach of the given cluster from the given volume set, in order to preserve consistency on the volumes in the set and avoid losing data.

0x8a52601f

ERROR

The system did not allow the automatic majority detach of missing clusters on the given volume set.

0x8a403008

WARNING

Crash consistency has been lost on the given async consistency group, due to unplanned loss of data, or inability to write a crash-consistent image.

0x8a40901d

CRITICAL

The "active-cluster-wins" rule-set has been set on the given consistency group, and the given cluster has departed.

0x8a250018

INFO

NDU of the VPLEX has finished successfully.

0x8a256019

ERROR

NDU of the VPLEX encountered a problem.

0x8A486197

ERROR

The Management Module is not present in the specified slot.

0x8A486198

ERROR

The operational state of the management module has changed to faulted.

0x8A48619A

ERROR

The FC I/O Module is not present in the specified slot.

0x8A48619E

ERROR

The power supply in the specified slot is in faulted state.

0x8A48926C

CRITICAL

The input air temperature to the power supply has exceeded the threshold levels.

0x8A4861A0

ERROR

The fan in the specified slot has faulted.

0x8A489259

CRITICAL

The speed of the fan has dropped below the threshold value.

0x8A4861B9

ERROR

The SPS is in a faulted state.

0x8A48925A

CRITICAL

The temperature of the enclosure has exceeded the threshold and a result of which the director is shutting down.

0x8A4830D7

WARNING

The director fault code represents the last hardware operation or a hardware fault.

0x8A4861A7

ERROR

A communication failure has been reported while attempting to contact the UPS.

0x8A4861A8

ERROR

The state of the I/O Annex is faulted

0x8A4861BB

ERROR

The UPS is in a faulted state.

0x8A48925D

CRITICAL

This could be due to faulty serial port on management module, faulty serial cable between the management module and the UPS, faulty UPS or missing UPS in the cluster.

0x8A4830DE

WARNING

The UPS has a problem with its charging hardware.

0x8A4861A9

ERROR

The I/O Module is not present in the specified slot of the I/O Annex.

0x8A4861AB

ERROR

The Gigabit Ethernet I/O Module is not present in the specified slot.

0x8A48926D

CRITICAL

The power supply is not present in the specified slot.

0x8A4861AE

ERROR

The fan in the specified slot is not present.

0x8A489264

CRITICAL

Fans in the specified slots are in faulted state.

0x8A4861B1

ERROR

The midplane is not present in the specified slot.

0x8A4861B2

ERROR

The operating status of the director is faulted.

0x8A4861B3

ERROR

The director specified is not present in the engine.

0x8A4861B4

ERROR

The state of the FC I/O Module has changed to faulted.

0x8A4861B5

ERROR

The state of the Gigabit Ethernet I/O Module has changed to faulted.

0x8A4861B6

ERROR

The state of the SSD drive has changed to faulted.

0x8A4861B7

ERROR

The SSD drive could not be detected in the director.

0x8A4861B8

ERROR

The configuration on the ethernet switch of the management module could not be updated due to a software failure.

0x8A4861C5

ERROR

The SSD drive on the director failed.

0x8A48925E

CRITICAL

The power and environment monitoring process failed due to an internal error.

0x8A489269

CRITICAL

An internal hardware error has been detected on one of the directors.

0x8A48926A

CRITICAL

An internal hardware error has been detected on one of the directors.

0x8A4a31F4

WARNING

Management of remote and distributed resources is no longer possible.

0x8A4a61F6

ERROR

The Host Certificate will expire within a week.

0x8A4a61F7

ERROR

The CA certificate will expire in a week.

0x8A4a91F8

CRITICAL

Your CA certificate has expired.

0x8A4a91F9

CRITICAL

Your Host certificate has expired.

0x8A4a61FA

ERROR

A partition on your Management Server has exceeded a critical capacity threshold.

0x8A4a31FB

WARNING

A partition on your Management Server has reached a high capacity.

0x8a363014

WARNING

Some amount of IO failure on a login due to dropped frames.

0x8a369015

CRITICAL

Some amount of IO failed because frames timed out.

0x8a369018

CRITICAL

A Fibre Channel port is continuously toggling between linkup and linkdown.

0x8a36301a

WARNING

The RX Power level on a Fibre Channel port is below the low limit and IO timeouts have occurred.

0x8a36901c

CRITICAL

The EMC part number of the SFP was not recognized.

0x8a36301d

WARNING

The port is equipped with an SFP with approved EMC part number for this product, but the vendor part number is not on the recognized list.

0x8a363030

WARNING

An FC chip detected persistent PCI error.

0x8a363034

WARNING

Interface received frames with EOFa (End of Frame Abort) delimiter in the last minute.

0x8a363035

WARNING

Interface discarded frame(s) in the last minute.

0x8a363036

WARNING

Interface received frames with CRC error in the last minute.

0x8a363037

WARNING

Interface received frames with protocol error in the last minute.

0x8a363039

WARNING

An FC port is being turned off because RX power low and IO timeout.

0x8a36303a

WARNING

An FC port's TX power is too low.

0x8a4b9000

CRITICAL

The filesystem monitor failed to retrieve the status of one of the filesystems that it was monitoring.

0x8a4b9001

CRITICAL

A filesystem has exceeded its usage threshold and is getting low on free space.

0x8A4830D8

WARNING

The temperate of the I/O Annex is nearing the error threshold levels due to some environmental conditions.

0x8A4830DB

WARNING

Conditioning of an SPS has been missed for two cycles.

0x8A4830DC

WARNING

The fibre channel switch and/or management server are not plugged in to the UPS.

0x8A4861C7

ERROR

The I/O Annex is not present in the specified slot.

0x8A4861C8

ERROR

An I/O Annex fuse has faulted.

0x8A4861C9

ERROR

A fan in the I/O Annex has faulted.

0x8A4830E7

WARNING

An internal PROM has become corrupted.

0x8A4861CE

ERROR

Unable to arbitrate for the top-level I2C mux.

0x8A4861CF

ERROR

Unable to arbitrate for the I2C bus.

0x8A4861D0

ERROR

Unable to configure the top-level I2C mux.

0x8A4861D1

ERROR

Configuration of the switches on the I2C bus failed.

0x8A4861D3

ERROR

The SCL signal on the specified I2C bus is shorted to ground.

0x8A489265

CRITICAL

The temperature of the I/O Annex has exceeded the threshold and a result of which the I/O Annex is shutting down.

0x8A489266

CRITICAL

Both fans in the I/O Annex have faulted.

0x8A4830E9

WARNING

The specified FRU cannot be accessed.

0x8A4861D6

ERROR

The specified FRU is not present.

0x8A4861D7

ERROR

The state of the specified FRU is faulted

0x8A4830EA

WARNING

Memory configuration error has been detected.

0x8A4830EB

WARNING

An internal hardware error has been detected.

0x8A4830EC

WARNING

An error occurred accessing an NVRAM log.

0x8A4861DA

ERROR

An SPS conditioning cycle has failed because the battery can no longer hold a sufficient charge.

0x8A4E9002

CRITICAL

The cluster has started vaulting either because user initiated a manual vault or due to a persistent power and/or environmental conditions.

0x8A4E900D

CRITICAL

Vault recovery on the cluster cannot proceed because all director(s) required to complete recovery are either not operational or communicating.

0x8A4E9015

CRITICAL

The director(s) in the cluster are taking more than expected time to quiesce IO and freeze the cache for vaulting.

0x8A4C9259

CRITICAL

GeoSynchrony has failed three times continuously.

0x8A4C925A

CRITICAL

GeoSynchrony has failed due to an internal error.

0x8a519001

CRITICAL

Errors have been detected that prevent the director from starting fully.

0x8a519002

CRITICAL

Errors have been detected that prevent the director from starting fully.

0x8a519003

CRITICAL

Errors have been detected that prevent the director from starting fully.

0x8A4A3002

WARNING

Automated meta-volume backup has not been properly configured, or the configuration file was removed.

0x8A4A3003

WARNING

One, or both, Storage volumes reserved for automated meta-volume backup are used by manually created meta-volume backups.

0x8A4A6007

ERROR

Detected incorrect number of storage-volumes configured for automated meta-volume backup.

0x8A4A6006

ERROR

The automated backup of the meta-volume could not be completed.

0x8a543013

WARNING

A communication port didn't reach link up in time.

0x8a543019

WARNING

The last redundant FC path to the specified VPLEX WAN-COM port is down.

0x8a54601b

ERROR

Stuck IO had been detected on an FC port.

0x8a54301d

WARNING

Large number of i/os have timed out on this connection in the past one minute.

0x8a559001

CRITICAL

A service has stopped running because it has encountered multiple failures.

0x8a556002

ERROR

A service has stopped running because it has encountered multiple failures.

0x8a4A6067

ERROR

The queue of call-home events being processed hit the length of the queue.

0x8a4A0065

INFO

Attempting to resume normal monitoring

0x8a4A0066

INFO

Attempting to resume normal monitoring

0x8a343022

WARNING

Scsi xcopy command processing is disabled on VPLEX.

0x8a346026

ERROR

A xcopy command was aborted because of a system memory allocation failure.

0x8a346027

ERROR

A xcopy command was aborted because of a slab memory allocation failure.

0x8a349035

CRITICAL

An IO failed to complete or be properly aborted and cleaned up.

Impact diagram v1

EMC Vplex internal impact diagram(EMC Vplex device and components)

[VplexDevice]-impacts>[Engine]

[VplexDevice]-impacts>[Cluster]

[Engine]-impacted by>[Fan]

[Engine]-impacted by>[PowerSupply]

[Engine]-impacted by>[VplexDevice]

[Fan]-impacts>[Engine]

[Fan]-impacted by>[PowerSupply]

[PowerSupply]-impacts>[Fan]

[PowerSupply]-impacts>[Engine]

[ConsistencyGroup]-impacted by>[Cluster]

[StorageVolume]-impacts>[Lun]

[StorageVolume]-impacted by>[StorageArray]

[VirtualVolume]-impacted by>[Extent]

[Cluster]-impacted by>[VplexDevice]

[Cluster]-impacts>[StorageArray]

[Cluster]-impacts>[ConsistencyGroup]

[Extent]-impacts>[VirtualVolume]

[Extent]-impacted by>[StorageVolume]

[StorageVolume]-impacts>[Extent]

[Extent]-impacted by>[LocalDevice]

[LocalDevice]-impacts>[Extent]

[StorageArray]-impacts>[StorageVolume]

[StorageArray]-impacted by>[Cluster]

[Lun]-impacted by>[StorageVolume]

Changelog

  • 1.1.0

    • Add REST based modeling and monitoring.