EMC ECS Integration Service
Support
This ZenPack is developed and supported by Virtana. Enterprise support is available to Virtana customers with an active subscription or support agreement. ZenPacks are available at delivery.zenoss.com. To request more information about this or any other ZenPack, contact Virtana.
This ZenPack is developed and supported by Virtana Professional Services, and is a supplemental monitoring offering to the standard Virtana product subscription or support agreement. These are offered as separate subscriptions in order to provide initial setup, training, and ongoing compatibility and maintenance. All standard packages are renewable every 12 months from the date of purchase. Contact Virtana to request more information regarding this or any other ZenPacks.
Name
EMC ECS Integration Service
Release:
1.0.2
About
This ZenPack provides the capability to model and monitor Dell EMC ECS cluster using ECS Management API and adapt Alerts raised by the ECS system to Virtana events.
Prerequisites
Prerequisite | Restriction |
|---|---|
Product | Zenoss 6.0.1 or higher |
Required ZenPacks | ZenPacks.zenoss.PS.Util >= 1.9.6 ZenPacks.zenoss.ZenPackLib >= 2.0 |
COMPAT_ZENOSS_VERS | >=6.0.1 |
Other dependencies | None |
Usage
Add EMC ECS VDC Device to the "/Storage/EMC/ECS" Virtana DeviceClass. The device IP should be IP address of FQDN of an ECS node.
API Configuration
Configure the following zProperties to enable the API communication and successfully access the EMC ECS platform:
zECSAPIUserUser to access EmcEcs RestAPI. This is the user id of an ECS Management.
zECSAPIPasswordPassword to access EmcEcs RestAPI. This is the password for the ECS Management User.
zECSAPIPortThis is usually "4443" which is the ECS Management API port user.
zECSAPIUseSSLThis is usually true which is "https" Protocol.
zECSAPIResponseTimeoutThe number of seconds to wait for a HTTP response from the ECS API
Components Modeled
To add relationship between all Components the EMC ECS VDC should be modeled twice.
EMC ECS Monitoring Notes
EMC ECS Management API returns "Transaction Read/Write Bandwidth" and "Transaction Read/Write Latency" only as historical values with time delay of 15 minutes. So, these metrics are monitored every 5 minutes(by default), but displayed on graphs with a delay of 15 minutes.
Change Log
1.0.2
SVC-2736 Update to new PS.Util HTTP net_client logging standard
1.0.1
SVC-2736 HTTP API response timeout configurable
1.0.0
Initial release. Initial modeling and monitoring EMC ECS storage infrastructure via REST API