HP Proliant (Commercial)
ZenPacks.zenoss.HP.Proliant
This ZenPack provides support for monitoring HP Proliant Servers (G6, G7, G8, G9, and G10), including blade servers with the HP Proliant c7000 Enclosure. Discovery and monitoring are performed using SNMP, iLO (XML/HTTP), and/or WBEM protocols depending on environment.
This ZenPack currently supports HP Proliant servers running Windows or Linux (with installed/configured HP SIM SNMP subagent), HP Enclosures (via SNMP) as well as iLO devices (via either iLO or SNMP) and VMWare ESXi (using HP custom ESXi with WBEM/CIM access configured).
It is important to note that not all features of this ZenPack are supported across all protocols, since each of them provides a part, but not all, of the total information used by the ZenPack. This limitation is based on the amount and quality information that is available from each of the supported protocol. What this means is that certain metrics for a given component type (such as a temperature sensor) may or may not be available depending on the type of device that is monitored and/or on the protocol used to collect that data.
The features added by this ZenPack can be summarized as follows. They are each detailed further below.
Initial discovery and continual synchronization of relevant components
Performance monitoring
Event management and monitoring
Command line utilities for troubleshooting and diagnostics
Optional Service Impact with addition of Virtana Service Dynamics product
Releases
Version 3.3.5
Release on 2020/05/21
Requires WBEM ZenPack, PythonCollector ZenPack (>=1.2), ZenPackLib ZenPack (>=2.0.6)
Compatible with Zenoss 4.2.5-6.4.1 and Virtana Service Observability
Version 3.2.2
Release on 2017/04/03
Requires WBEM ZenPack, PythonCollector ZenPack (>=1.2)
Compatible with Zenoss Core 4.2.x, Zenoss Core 5.0.x, Zenoss Core 5.1.x, Zenoss Core 5.2.x, Virtana Service Dynamics 4.2.x, Virtana Service Dynamics 5.0.x, Virtana Service Dynamics 5.1.x, Virtana Service Dynamics 5.2.x
External Dependencies
This ZenPack relies on several protocols to achieve coverage of various aspects of the HP Proliant architecture. At the most basic level, SNMP should be configured so as to facilitate access to HP/Compaq MIBs (CPQSINFO-MIB, CPQRACK-MIB, and so on) and the associated OIDs. Support on a bare metal install of Linux or Windows OS, for example, requires installation of HP SIM and its associated software components, including an SNMP subagent and associated configuration for its use with the OS SNMP agent. Configuration of these software components is covered by various documentation available from HP and is beyond the scope of this document.
SNMP is also supported natively by HP OnboardAdministrator (if available) and optionally by the iLO management interface.
As noted above, the iLO management interface can be monitored (as a Virtana device) via iLO protocol (essentially XML via HTTP) or SNMP (which can be enabled in the iLO GUI interface).
An additional important item to note is that the iLO management interface GUI requires that the associated server's FQDN and IP address be set manually. This ZenPack requires the configuration of FQDN (or hostname) and IP to be set in order for Virtana to create associations on its side between monitored Proliant servers and their associated iLO device in Virtana.
Support for HP Proliant hardware running VMware ESXi OS relies on a custom ESXi image available from HP. This custom image provides support for Proliant-specific monitoring and performance data that is not available using the version of ESXi provided by VMware. Additionally, WBEM support must be configured and enabled on the ESXi host.
Discovery
The following components will be automatically discovered using either the SNMP, iLO, or WBEM related connection parameters you provide. The properties and relationships will be continually updated on Virtana' normal remodeling interval which defaults to every 12 hours.
HPEnclosure
Attributes: Firmware Version, Model, Part Number, Serial Number, Spare Part Number
Relationships: Cooling Fan, Device Bay, Interconnect Bay, Onboard Administrator, Power Supply, Temp Sensor, HPTemperatureSensors, HPThermalSubsystem
HPDeviceBay
Attributes: BIOS Revision, Blade Device Link, Firmware Version, Part Number, Product ID, Service Tag, Slot Number, Spare Part Number
Relationships: Enclosure
HPEnclosureCoolingFan
Attributes: Location, Part Number, Present, Redundant, Spare Part Number
Relationships: Enclosure
HPInterconnectBay
Attributes: Product Name, Location, Part Number, Present, Serial Number, Spare Part Number, Switch Index
Relationships: Enclosure
HPOnboardAdmin
Attributes: OAIndex, UUID, Bay Number, Part Number, Present, Redundant, Role, Serial Number, Spare Part Number, Enclosure Serial Number
Relationships: Enclosure
HPTemperatureSensor
Attributes: Location, Threshold, Threshold Type
Relationships: Enclosure
HPChassis
Attributes: Total RAM, Product ID, Product, Server Name, Serial Number, Enclosure Manager Serial, Enclosure Manager Name, Enclosure Manager IP, Enclosure Manager URL
Relationships: Processor, Cooling Fan, Logical Drive, Management Controller, Memory Slot, Network Interface, NIC, HPOSHypervisor, PCI Device, Physical Drive, Power Supply, System Board, Temp Sensor, RAID Controller, FC Adapter, FC Port
HPFibreChannelAdapter
Attributes: Description, Device ID
Relationships: Chassis, FC Port
HPFibreChannelPort
Attributes: Description, Device ID, WWN, WWPN
Relationships: Chassis, FC Adapter
HPCoolingFan
Attributes: Name, Type, Hot Plug, Location, Present, Redundant
Relationships: Chassis
HPArrayController
Attributes: Model, Firmware Revision, Slot, Product Revision, Partner Slot, Serial Number, Daughter Board Type, HW Location, Number of Buses, Rebuild Priority, Expand Priority, Internal Ports, External Ports, Write Cache, Partner Serial Number, ROM Revision, Encryption
Relationships: Chassis, Logical Drive, Physical Drive
HPLogicalDrive
Attributes: Redundant, Capacity, Stripe Size
Relationships: Chassis, RAID Controller
HPManagementController
Attributes: Firmware Version, Firmware Date, ipv4 Address, Active License Type, Model, Serial Number, Security Override Switch, url
Relationships: Chassis
HPMemory
Attributes: Module Number, Cpu Number, Frequency, Size, Type, Technology
Relationships: Chassis
HPNetworkInterface
Attributes: AutoSense, Capabilities, Description, Full Duplex, Link Technology, MTU, Max Speed, Name, Port Number, Port Type, Speed
Relationships: Chassis
HPNetworkInterfaceController
Attributes: MAC Address, ID, Type, IP Address, Description
Relationships: Chassis
HPPCIDevice
Attributes: Physical Slot, Board Name, Slot Type, Slot Width
Relationships: Chassis
HPPhysicalDrive
Attributes: Capacity, Firmware, Model, Speed, Location, Manufacturer, productId, Serial Number
Relationships: Chassis, RAID Controller
HPPowerSubsystem
Attributes: Part Number, Serial Number, Max Output, Present, sparePartNumber
Relationships: Enclosure
HPServerPowerSupply
Attributes: Part Number, Serial Number, Max Output, Redundant, Present,
HPProcessor
Attributes: L1, L2, L3, Coprocessor Count, Coprocessor Speed, Coprocessor Type, Cores, HyperThread, Model, Socket, Speed, Stepping, Thread Count
Relationships: Chassis
HPSystemBoard
Attributes: Product Name, ROM Version, Serial Number, TPM Module
Relationships: Chassis
HPTemperature
Attributes: Location, Threshold, Threshold Type
Relationships: Chassis
Monitoring
The following metrics will be collected every 5 minutes by default. The average statistic is collected, and the graphed value is per second for anything that resembles a rate.
- HPFibreChannelAdapter
Protocol
Metrics
WBEM
—
- HPFibreChannelPort
Protocol
Metrics
SNMP
cpqFcaHostCntlrCondition,cpqFcaHostCntlrStatusWBEM
FramesTooLong,EncodingDisparityErrors,RXBroadcastFrames,ErrorFrames,MulticastFramesTransmitted,LossOfSyncCounter,LinkFailures,LinkResetsReceived,BytesReceived,DumpedFrames,FramesTooShort,CRCErrors,PacketsReceived,PacketsTransmitted,LossOfSignalCounter,TXBroadcastFrames,DelimiterErrors,LinkResetsTransmitted,PrimitiveSeqProtocolErrCount,BytesTransmitted,AddressErrors,MulticastFramesReceived- HPChassis
Protocol
Metrics
SNMP
statusILO
statusWBEM
status- HPCoolingFan
Protocol
Metrics
SNMP
status,speedILO
status,speedWBEM
status,speed- HPDeviceBay
Protocol
Metrics
SNMP
status,cpqRackServerBladeWattageAvg,cpqRackServerBladePOSTStatus,cpqRackServerBladePowered,condition- HPEnclosure
Protocol
Metrics
SNMP
status- HPEnclosureCoolingFan
Protocol
Metrics
SNMP
status- HPArrayController
Protocol
Metrics
SNMP
cpqDaAccelBattery,cpqDaCntlrPerfCpuPercentBusy,cpqDaAccelWriteErrs,cpqDaCntlrBoardStatus,cpqDaAccelBadData,cpqDaCntlrBoardCondition,cpqDaAccelStatus,cpqDaAccelErrCode,cpqDaCntlrPerfAvgLatency,cpqDaAccelReadErrs,cpqDaCntlrCondition,cpqDaAccelCondition,cpqDaCntlrPerfCommandCount,cpqDaCntlrPartnerBoardStatusILO
cpqDaAccelBattery,cpqDaCntlrCondition,cpqDaCntlrBoardStatusWBEM
cpqDaAccelBattery,CacheReadPercent,cpqDaAccelStatus,CacheParityReadErrors,CacheModuleTemperature,ControllerTemperature,CacheParityWriteErrors,cpqDaCntlrCondition,CacheWritePercent- HPLogicalDrive
Protocol
Metrics
SNMP
status,sectorsRead,condition,driveWrite,driveRead,sectorsWriteILO
conditionWBEM
status- HPManagementController
Protocol
Metrics
SNMP
status,cpqSm2CntlrBatteryStatus,interfaceStatus,cpqSm2CntlrPendingAlerts,cpqSm2NicCondition,cpqSm2CntlrVideoStatus,cpqSm2CntlrAlertStatus,cpqSm2CntlrKeyboardCableStatus,cpqSm2CntlrRemoteSessionStatusILO
statusWBEM
status- HPMemory
Protocol
Metrics
SNMP
status,conditionILO
statusWBEM
status- HPNetworkInterface
Protocol
Metrics
WBEM
status,BytesReceived,PacketsReceived,PacketsTransmitted,InternalMACReceiveErrors,InternalMACTransmitErrors,BytesTransmitted- HPNetworkInterfaceController
Protocol
Metrics
ILO
status- HPOnboardAdmin
Protocol
Metrics
SNMP
status- HPPhysicalDrive
Protocol
Metrics
SNMP
cpqDaPhyDrvHardWriteErrs,cpqDaPhyDrvDrqTimeouts,cpqDaPhyDrvHardwareErrs,cpqDaPhyDrvWrites,cpqDaPhyDrvOtherTimeouts,cpqDaPhyDrvFormatErrs,cpqDaPhyDrvBadTargetErrs,cpqDaPhyDrvCondition,cpqDaPhyDrvMediaErrs,cpqDaPhyDrvReads,status,cpqDaPhyDrvHardReadErrs,cpqDaPhyDrvNotReadyErrsILO
statusWBEM
MediaFailures,ReadOperations,HardwareErrors,SectorsWritten,SectorsRead,OtherTimeOuts,BadTargetErrors,WriteOperations,status,NotReadyErrors,HardReadErrors,DRQTimeOuts,FormatErrors,HardWriteErrors- HPPowerSubsystem
Protocol
Metrics
SNMP
status,currentPowerSupply,condition- HPServerPowerSupply
Protocol
Metrics
SNMP
status,currentPowerSupply,conditionILO
status- HPProcessor
Protocol
Metrics
SNMP
statusILO
statusWBEM
status- HPSystemBoard
Protocol
Metrics
SNMP
hoursInService- HPTemperature
Protocol
Metrics
SNMP
status,currentReadingILO
status,currentReadingWBEM
status,currentReading- HPTemperatureSensor
Protocol
Metrics
SNMP
status,currentReading
Event Management
Event management is handled both actively and passively. Passively, this takes the form of SNMP traps, translations and correlations for which 516 notifications defined in the various HP/Compaq MIBs are included in the form of Event class instances with transforms.
Active Event management revolves around the tracking of the numeric state indicators defined variously according to SNMP, ILO, or WBEM and mapped to corresponding Virtana event severities.
- Enclosure
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Device Bay
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
snmp
cpqRackServerBladePOSTStatus is Other or Started or Completed
Clear Event
snmp
condition is Other or True
Warning Event
snmp
status is Degraded
Warning Event
snmp
cpqRackServerBladePOSTStatus is Failed
Warning Event
snmp
condition is False or Power Staged Off or Reboot
Critical Event
snmp
status is Failed
- Cooling Fan (Enclosure)
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Temp Sensor (Enclosure)
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Warning Event
snmp
status is Degraded
Critical Event
snmp
status is Failed
- Interconnect Bay
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Chassis
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Cooling Fan
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is OK
Clear Event
snmp
speed is Other or Normal
Clear Event
esx
speed is OK
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded
Warning Event
snmp
speed is High
Warning Event
esx
speed is Degraded
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure
Critical Event
esx
speed is Major Failure
- FC Adapter
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- FC Port
Event
Protocol
Condition
Clear Event
snmp
cpqFcaHostCntlrCondition is Other or OK
Clear Event
snmp
cpqFcaHostCntlrStatus is Other or OK
Debug Event
snmp
cpqFcaHostCntlrCondition is Not Connected
Debug Event
snmp
cpqFcaHostCntlrStatus is Not Connected
Warning Event
snmp
cpqFcaHostCntlrCondition is Shut Down or Loop Degraded
Warning Event
snmp
cpqFcaHostCntlrStatus is Degraded or Loop Degraded
Error Event
snmp
cpqFcaHostCntlrCondition is Loop Failed
Error Event
snmp
cpqFcaHostCntlrStatus is Loop Failed
Critical Event
snmp
cpqFcaHostCntlrCondition is Failed
Critical Event
snmp
cpqFcaHostCntlrStatus is Failed
- RAID Controller
Event
Protocol
Condition
Clear Event
snmp
cpqDaAccelBattery is Other or OK
Clear Event
snmp
cpqDaCntlrBoardStatus is Other or OK or Disabled
Clear Event
snmp
cpqDaAccelBadData is Other or None
Clear Event
snmp
cpqDaCntlrBoardCondition is Other or OK
Clear Event
snmp
cpqDaAccelStatus is Other or Invalid or Enabled
Clear Event
ilo
cpqDaCntlrCondition is Other or OK
Clear Event
snmp
cpqDaCntlrCondition is Other or OK
Clear Event
snmp
cpqDaAccelCondition is Other or OK
Clear Event
snmp
cpqDaCntlrPartnerBoardStatus is Other or OK or Disabled
Debug Event
snmp
cpqDaAccelBattery is Missing
Debug Event
snmp
cpqDaAccelStatus is Not Attached
Debug Event
ilo
cpqDaCntlrCondition is Not Installed
Info Event
snmp
cpqDaAccelBattery is Recharging
Warning Event
snmp
cpqDaAccelBattery is Degraded
Warning Event
snmp
cpqDaCntlrBoardStatus is Cable Fault or Failed
Warning Event
snmp
cpqDaAccelBadData is Possible
Warning Event
snmp
cpqDaCntlrBoardCondition is Degraded
Warning Event
snmp
cpqDaAccelStatus is Temporarily Disabled or Degraded or Read Cache Unmapped
Warning Event
ilo
cpqDaCntlrCondition is Degraded or Degraded
Warning Event
snmp
cpqDaCntlrCondition is Degraded
Warning Event
snmp
cpqDaAccelCondition is Degraded
Error Event
snmp
cpqDaAccelBattery is Failed or Capacitor Failed
Error Event
snmp
cpqDaAccelStatus is Permanently Disabled
Error Event
ilo
cpqDaCntlrCondition is Major Warning
Critical Event
snmp
cpqDaCntlrBoardStatus is Failed
Critical Event
snmp
cpqDaCntlrBoardCondition is Failed
Critical Event
snmp
cpqDaAccelStatus is Critical Failure
Critical Event
ilo
cpqDaCntlrCondition is Failed
Critical Event
snmp
cpqDaCntlrCondition is Failed
Critical Event
snmp
cpqDaAccelCondition is Failed
Critical Event
snmp
cpqDaCntlrPartnerBoardStatus is Failed
- Logical Drive
Event
Protocol
Condition
Clear Event
ilo
status is Other or OK
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Clear Event
ilo
condition is OK
Clear Event
snmp
condition is Other or OK
Warning Event
ilo
status is Unconfigured or Recovering or Ready For Rebuild or Rebuilding or Wrong Drive or Bad Connect or Over heating or Shutdown or Expanding or Not Available or Queued For Expansion or Multipath Access Degraded or Erasing or Predictive Spare Rebuild Ready or Rapid Parity Init In Progress or Rapid Parity Init Pending
Warning Event
snmp
status is Unconfigured or Recovering or Ready For Rebuild or Rebuilding or Wrong Drive or Bad Connect or Over heating or Shutdown or Expanding or Not Available or Queued For Expansion or Multipath Access Degraded or Erasing or Predictive Spare Rebuild Ready or Rapid Parity Init In Progress or Rapid Parity Init Pending
Warning Event
esx
status is Degraded or Minor Failure
Warning Event
snmp
condition is Degraded
Critical Event
ilo
status is Failed
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
Critical Event
ilo
condition is Failed
Critical Event
snmp
condition is Failed
- Management Controller
Event
Protocol
Condition
Clear Event
snmp
status is Other or Online
Clear Event
esx
status is Unknown or OK
Clear Event
snmp
cpqSm2CntlrBatteryStatus is Other or OK
Clear Event
snmp
interfaceStatus is Other or OK
Clear Event
snmp
cpqSm2CntlrPendingAlerts is Other or None
Clear Event
snmp
cpqSm2CntlrVideoStatus is Other or Enabled
Clear Event
snmp
cpqSm2CntlrAlertStatus is Other or Enabled
Clear Event
snmp
cpqSm2CntlrRemoteSessionStatus is Other or Inactive
Clear Event
snmp
cpqSm2CntlrKeyboardCableStatus is Other or Connected or Disconnected
Debug Event
snmp
cpqSm2CntlrVideoStatus is Disabled
Debug Event
snmp
cpqSm2CntlrAlertStatus is Disabled
Debug Event
snmp
cpqSm2CntlrRemoteSessionStatus is Active
Warning Event
snmp
status is No Data or Offline
Warning Event
esx
status is Degraded
Warning Event
snmp
cpqSm2CntlrBatteryStatus is Disconnected
Warning Event
snmp
interfaceStatus is Not Responding
Warning Event
snmp
cpqSm2CntlrPendingAlerts is Pending or Remaining
Critical Event
esx
status is Major failure
Critical Event
snmp
cpqSm2CntlrBatteryStatus is Failed
- Memory Slot
Event
Protocol
Condition
Clear Event
ilo
status is Other or OK or Not Present or Good
Clear Event
snmp
status is Other or Not Present or In Use or Spare
Clear Event
esx
status is Unknown or OK or Degraded
Clear Event
snmp
condition is Other or OK
Info Event
snmp
status is Present or Added or Upgraded or Unmatched or Partial Use
Warning Event
ilo
status is Degraded or Degraded Module Index Unknown
Warning Event
snmp
status is Missing or Not Supported or Bad Configuration
Warning Event
snmp
condition is Degraded or Degraded Module Index Unknown
Error Event
snmp
status is Degraded
- Network Interface
Event
Protocol
Condition
Clear Event
esx
status is OK or Degraded or MajorFailure
- NIC
Event
Protocol
Condition
Clear Event
ilo
status is Other or OK
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Debug Event
ilo
status is Disabled
Debug Event
snmp
status is Unknown
Warning Event
ilo
status is Link Down
Warning Event
snmp
status is Link Down
Warning Event
esx
status is Degraded or Minor Failure
Error Event
esx
status is Major Failure or Non-recoverable Error
Critical Event
esx
status is Critical Failure
- Onboard Administrator
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- PCI Device
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Physical Drive
Event
Protocol
Condition
Clear Event
ilo
status is Other or OK
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Clear Event
snmp
condition is Other or OK
Warning Event
ilo
status is Predictive Failure or Erasing or Erase Done or Erase Queued or SSD Wear Out or Degraded (Not Authenticated)
Warning Event
snmp
status is Predictive Failure or Erasing or Erase Done or Erase Queued or SSD Wear Out or Degraded (Not Authenticated)
Warning Event
esx
status is Degraded or Minor Failure
Warning Event
snmp
condition is Degraded
Critical Event
ilo
status is Failed
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
Critical Event
snmp
condition is Failed
- Power Supply
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
snmp
condition is No Error
Warning Event
snmp
status is Degraded
Critical Event
snmp
status is Failed
Critical Event
snmp
condition is General Failure or Bist Failure or Fan Failure or Temp Failure or Inter Lock Open or Eprom Failed or Vref Failed or Dac Failed or Ram Test Failed or Voltage Channel Failed or Orring Diode Failed or Brown Out or Give Up On Startup or Nvram Invalid or Calibration Table Invalid
- Power Supply (2)
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
snmp
condition is No Error
Warning Event
snmp
status is Degraded
Critical Event
snmp
status is Failed
Critical Event
snmp
condition is General Failure or Bist Failure or Fan Failure or Temp Failure or Inter Lock Open or Eprom Failed or Vref Failed or Dac Failed or Ram Test Failed or Voltage Channel Failed or Orring Diode Failed or Brown Out or Give Up On Startup or Nvram Invalid or Calibration Table Invalid
- Processor
Event
Protocol
Condition
Clear Event
ilo
status is OK
Clear Event
snmp
status is OK
Clear Event
esx
status is OK
Debug Event
ilo
status is Unknown
Debug Event
snmp
status is Unknown
Debug Event
esx
status is Unknown
Info Event
ilo
status is Disabled
Info Event
snmp
status is Disabled
Warning Event
ilo
status is Degraded
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Stopped
Critical Event
ilo
status is Failed
Critical Event
snmp
status is Failed
Critical Event
esx
status is Predictive Failure or Error
- System Board
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK
Clear Event
esx
status is Unknown or OK
Info Event
snmp
status is Disabled
Warning Event
snmp
status is Degraded
Warning Event
esx
status is Degraded or Minor Failure or Error
Critical Event
snmp
status is Failed
Critical Event
esx
status is Major Failure or Critical Failure or Non-recoverable Error
- Temp Sensor
Event
Protocol
Condition
Clear Event
snmp
status is Other or OK or Not Installed
Warning Event
snmp
status is Degraded
Critical Event
snmp
status is Failed
Service Impact
When combined with the Virtana Service Dynamics product, this ZenPack adds built-in service impact and root cause analysis capabilities for services running on HP Proliant. The service impact relationships shown in the diagram and described below are automatically added. These will be included in any services that contain one or more of the explicitly mentioned components.
Service Impact Relationships:
Device impacts related Enclosure
Chassis: Enclosure impacts related Device Bay, Cooling Fan, Interconnect Bay, Power Subsystem, Temperature Sensor
Chassis impacts related Processor, Memory, System Board, Temperature Sensor, Cooling Fan, Power Supply, Management Controller, Network Interface, Onboard Administrator, PCI Device, Array Controller, Physical Drive, Logical Drive, Fibre Channel Adapter, Fibre Channel Controller
Fibre Channel Adapter impacts related Fibre Channel Port
Array Controller impacts related Logical Drive, Physical Drive
Device Bay impacts related Chassis
Management Controller impacts related Device (iLO)
Data Collection
The HP Proliant ZenPack uses several methods to collect both model and performance data depending on the device types, which fall into 3 categories:
SNMP
Onboard Administrator is HP's solution for hardware management and monitoring. It provides a SNMP interface that Virtana uses to monitor both HP chassis and blade hardware as well as certain OS components with the OA agent installed and configured. SNMP access can also be configured for use with the iLO management interface (via the managment GUI) or with a bare metal install of Linux or Windows by installing HP SIM and related software (including its SNMP subagent)
ILO
Data from ILO devices is provided by a HTTPS interface listening on port 443. The zILOUserName, zILOPassword, zILOUseSSL, and zILOPort zProperties control access to ILO devices. The ILO interface accepts and returns XML-formatted query strings, and this ZenPack features a custom api definining these queries and their output formatting.
WBEM
WBEM support is required for montitoring ESXi on HP Proliant hardware. The zWBEMUsername, zWBEMPassword, zWBEMPort, and zWBEMUseSSL zProperties control access to HP ESXi devices. Data collection relies on the WBEM ZenPack, and also uses a HTTP-based protocol (WBEM). HP provides custom-built ESXi ISOs that provide the HP WBEM software to the base ESXi image.
Endpoint configuration is beyond the scope of this document, but online resources are available at http://h10032.www1.hp.com/ctg/Manual/c04341228
Usage
Adding SNMP Onboard Administrator Device (Enclosure)
Use the following steps to start monitoring the Onboard Administrator using the web interface.
Navigate to the Infrastructure page.
Navigate to organizer Devices/Server/HP/OnboardAdministrator.
Choose Add a Single Device from the add button
Fill out the form:
Name can be anything you want.
Hostname or IP must be resolvable and accessible from the collector server chosen in the Collector field.
Click ADD.
Adding Linux SNMP or Windows (SNMP) Blade/Rack Device
Use the following steps to start monitoring Linux HP Proliant device using the web interface.
Navigate to the Infrastructure page.
Navigate to organizer Devices/Server/HP/Proliant.
Choose Add a Single Device from the add button
Fill out the form:
Name can be anything you want.
Hostname or IP must be resolvable and accessible from the collector server chosen in the Collector field.
Click ADD.
Adding ILO Device
Use the following steps to start monitoring a HP ILO device using the web interface.
Navigate to the Infrastructure page.
Navigate to organizer Devices/Server/HP/ILO.
Choose Add a Single Device from the add button
Fill out the form:
Name can be anything you want.
Hostname or IP must be resolvable and accessible from the collector server chosen in the Collector field.
Click ADD.
Adding ILO Device (SNMP)
Use the following steps to start monitoring a HP ILO device using the web interface.
Navigate to the Infrastructure page.
Navigate to organizer Devices/Server/HP/ILO/SNMP.
Choose Add a Single Device from the add button
Fill out the form:
Name can be anything you want.
Hostname or IP must be resolvable and accessible from the collector server chosen in the Collector field.
Click ADD.
Adding ESXi Device
Use the following steps to start monitoring a HP ILO device using the web interface.
Navigate to the Infrastructure page.
Navigate to organizer Devices/Server/VMware/ESXi/HP.
Choose Add a Single Device from the add button
Fill out the form:
Name can be anything you want.
Hostname or IP must be resolvable and accessible from the collector server chosen in the Collector field.
Click ADD.
Combining HP Proliant SNMP monitoring with existing Device Classes
Use the following steps to start monitoring a HP ILO device using the web interface.
Navigate to the Infrastructure page.
Navigate to the desired organizer containing SNMP-monitorable devices, such as Devices/Server/Linux.
Choose Details link above the Devices column
Select the Modeler Plugins menu item
Add the HP.snmp.HPSNMPModeler plugin to the list of Selected plugins
Click Save
Devices in this class should now model and monitor components as they are found
Command Line Tools
Several scripts are included for use with troubleshooting or sample data collection. These scripts reside in the $ZENPACK/ZenPacks/zenoss/HP/Proliant/utilities directory and calling --help will display usage information for each.
collect-samples-ilo.shperforms several queries against ILO devices and saves output to individual filescollect-samples-wbem.shperforms several queries against WBEM devices and saves output to individual fileshp-ilo-samples.pyexecute given ILO command against remote target and save outputhp-wbem-dump.pyoutput list of valid WBEM classnames from ESXi targethp-wbem-query.pyexecute WBEM query against remote ESXi targethp-wbem-smx-instancesperform exhaustive iteration of WBEM classes on remote ESXi target
Installed Items
Installing this ZenPack will add the following items to your Virtana system.
Device Classes
/Server/HP/OnboardAdministrator Enclosure monitoring
/Server/HP/ILO: iLO device monitoring with iLO
/Server/HP/ILO/SNMP: iLO device monitoring with SNMP
/Server/VMware/ESXi/HP: ESXi monitoring with WBEM
/Server/HP/Proliant: SNMP monitoring with HP MIBs
Configuration Properties
zILOPort
zILOUseSSL
zILOUserName
zILOPassword
zILOCollectSamples
Modeler Plugins
HP.snmp.HPEnclosureModele
HP.snmp.HPSNMPModeler
HP.ilo.HPILO3Modeler
HP.wbem.HPWBEMPlugin
Datasource Types
HP ILO Datasource
HP WBEM Datasource
SNMP Datasource (SNMP)
Monitoring Templates
HPArrayControllerILO
HPArrayControllerSNMP
HPArrayControllerWBEM
HPChassisILO
HPChassisSNMP
HPChassisWBEM
HPCoolingFanILO
HPCoolingFanSNMP
HPCoolingFanWBEM
HPDeviceBaySNMP
HPDeviceSNMP
HPEnclosureCoolingFanSNMP
HPEnclosureSNMP
HPFibreChannelAdapterWBEM
HPFibreChannelPortSNMP
HPFibreChannelPortWBEM
HPLogicalDriveILO
HPLogicalDriveSNMP
HPLogicalDriveWBEM
HPManagementControllerILO
HPManagementControllerSNMP
HPManagementControllerWBEM
HPMemoryILO
HPMemorySNMP
HPMemoryWBEM
HPNetworkInterfaceControllerILO
HPNetworkInterfaceWBEM
HPOnboardAdminSNMP
HPPhysicalDriveILO
HPPhysicalDriveSNMP
HPPhysicalDriveWBEM
HPPowerSubsystemSNMP
HPProcessorILO
HPProcessorSNMP
HPProcessorWBEM
HPServerPowerSupplyILO
HPServerPowerSupplySNMP
HPSystemBoardSNMP
HPTemperatureILO
HPTemperatureSNMP
HPTemperatureSensorSNMP
HPTemperatureWBEM
Component Types
Enclosure (HPEnclosure)
Chassis (HPChassis)
Cooling Fan (HPCoolingFan)
Device Bay (HPDeviceBay)
Cooling Fan (HPEnclosureCoolingFan)
Interconnect Bay (HPInterconnectBay)
RAID Controller (HPArrayController)
Logical Drive (HPLogicalDrive)
Management Controller (HPManagementController)
Memory Slot (HPMemory)
Network Interface (HPNetworkInterface)
NIC (HPNetworkInterfaceController)
Onboard Administrator (HPOnboardAdmin)
PCI Device (HPPCIDevice)
Physical Drive (HPPhysicalDrive)
Power Supply (HPPowerSubsystem)
Power Supply (HPServerPowerSupply)
Processor (HPProcessor)
System Board (HPSystemBoard)
Temp Sensor (HPTemperature)
Temp Sensor (HPTemperatureSensor)
FC Adapter (HPFibreChannelAdapter)
FC Port (HPFibreChannelPort)
Event Classes
/Status/HP
/Perf/HP
Required Daemons
Type | Name |
|---|---|
Modeler | zenmodeler |
Performance Collector | zenpython |
| zenperfsnmp |
Upgrade
The HP Proliant Zenpack can be upgraded. To upgrade the ZenPack, install the latest version over the existing one. There is no action for the user to migrate the data. The performance data and events of old ZenPack are retained as per the retain policy settings.
Limitations
Known Issues
Known Issue when monitoring systems with Failover Onboard Administrators
In order to fully support monitoring a system with multiple onboard administrators, the enclosure ip mode option must be enabled and the enclosure must be given a static IP address that is shared between the two onboard administrators. Failure to do so may cause monitoring to stop when the active onboard administrator goes offline.
Known Issue upgrading from 1.0 to 3.0
When upgrading from 1.0 to 3.0, you may see an issue related to catalogs. If you installed the ZenPack from the UI, the UI may report that the ZenPack install failed. As a workaround, install the ZenPack from the command line.
If you observe messages similar to the following:
WARNING zen.catalogservice: Detected catalog inconsistency - to repair, run: 'python /opt/zenoss/ZenPacks/ZenPacks.zenoss.CatalogService-1.0.19.10-py2.7.egg/ZenPacks/zenoss/CatalogService/sync_rids.py'
To finish the installation of this ZenPack, run the script as suggested, then restart the Zenoss instances.
Known issue regarding iLO unknown or N/A values
iLO device modelling reuses the original SNMP components of this ZenPack. Because the iLO does not return exactly the same results as are available via SNMP monitoring, there will be cases where some fields are always set to N/A or Unknown. This is a known issue and is not currently considered a defect.
Known issue regarding iLO monitoring
The servername variable must be set inside the iLO for this ZenPack to work properly with iLO hardware. For iLO 4, go to the iLO GUI under Administration → Access Settings. Under Access Options, update the Server Name field for the iLO server.
Known issue when removing ZenPack
Since this ZenPack depends on the PythonCollector ZenPack for some of its capabilities, the zenpython collector daemon should be stopped manually prior to uninstallation of this ZenPack in order to avoid a traceback error. The zenpython daemon can be restared again once uninstallation is complete.
Changes
3.3.5
Make zenpack compatible with twisted 19.10.0 (ZPS-6981)
Tested with Virtana Service Dynamics 6.4.1, Virtana Service Observability and Service Impact 5.5.1
3.3.4
Add log message to notify when "SERVER NAME" is blank in the iLO (ZPS-6128)
Tested with Virtana Service Dynamics 6.4.1, Virtana Service Observability and Service Impact 5.5.1
3.3.3
Updated icons with dark-theme compatible versions
ILO modeler timeout should follow zCollectorClientTimeout
Fix exceptions in impact relationship providers
Overhaul impact relationships
Hide credentials from logging (ZPS-4338)
Add support for ILO Gen 7 physical drives (ZPS-5274)
Fix WBEM component metric duplication issue (ZPS-6132)
3.3.2
Fix Error modeling Generation 9 iLO hardware when memory/swap info is missing (ZPS-3101)
Ensure all NICs are discovered and monitored (ZPS-3645)
Correct unrecognized "Good, In Use" status (ZPS-3737)
Modeling should succeed when drive enclosure is absent (ZPS-3306)
Update Physical Disk possible status values (ZPS-2946)
Tested with Zenoss 5.3.3, Zenoss 6.2.0, and Virtana Service Observability
3.3.1
Updated unit tests for build platform compatability (ZPS-29150, ZEN-28507)
3.3.0
Ported to ZenPackLib 2.0: Extend support to G9 and G10 platforms (ZPS-2086)
Add support for Fibre Channel Adapter and Port monitoring (ZPS-2086)
Added scripts for debug and data collection of iLO and WBEM clients
Revised monitoring template organziation and protocol dependency
Added new HP WBEM Datasource and revised all WBEM templates
Added multiple new metrics for WBEM monitoring
New icons added for device and all component classes
WBEM modeling and performance data collection completely revised
Additional mappings for SNMP traps (ZPS-679)
Fix bidirectional links on Device Status Page (ZPS-745, ZPS-2280)
Fix various SNMP modeling tracebacks (ZPS-1621)
Fix various issues during upgrade (ZPS-2088, ZPS-2256, ZPS-2257)
Fix various ILO modeling issues (ZPS-)
3.2.2
Fixed ILO and WBEM modeler plugins to better handle empty results
Updated list of recognized XML status strings
3.2.1
Updated ILO Protocol handler to address SSL certificate validation issue while preserving HTTP/1.1 compliance
Updated XML parser to better handle invalid XML output
Fix bad threshold datasource reference in HPArrayController template
Corrected type of cycletime parameter
Ensure all SNMP templates available to /Devices/Server/HP/ILO/SMNP
3.2.0
Added "HP Chassis List" and "HP Device Bay List" reports (ported from HPBladeChassis community ZP)
Update Impact documentation (ZEN-25324)
Added "zILOCollectSamples" zProperty (raw modeler output storage)
Updated zProperties (removed zProperty zILOSSLPort, replace with zILOUsesSSL and zILOPort)
Adjust component labels and titles for DynamicView (ZEN-25248)
Add ResetClassRelations migrate script (ZEN-25281)
Sensible thresholds for Temperature graphs (ZEN-25260)
More informative event logging (ZEN-24270)
Ensure that ILODatasource, HPStatusThreshold, and GUI use shared reference data
Updated graph datapoints and templates (ZEN-24886)
Improved datasource/datapoint access methdos for status string retrieval (ZEN-24277)
Fix traceback during WBEM modeling (ZEN-24786) updated and new unit testing to handle ILO datasource/modeler testing (ZEN-24810)
Revised and simplified all string-to-integer status mapping code
Added new ILOProtocolHandler ILO client (ZEN-25277)
Added new ILOXMLParser for shared access to ILO output
Added cross-reference functions to HPDevice and HPChassis (get_ilo, get_cpus, get_mem)
Revised shared component attributes for consistency
Remove/migrate code from utils.py and ErrorHandler.py
Added ManagedObject base to contine shared component code
deprecate ILO2 support (ZEN-22388)
Rewrite of all modeler plugins
Added HPPluginBase, HPSnmpPlugin to contain shared plugin code
Prevent premature data collection termination (ZEN-24277)
Add support for RAID controller monitoring via SNMP and ILO (ZEN-24211, ZEN-23388)
Fix HPStatusThreshold issue causing data collection to stop (ZEN-23040)
Improved handling of components with blank id (ZEN-22872, ZEN-22851, ZEN-21680)
3.1.1
Updated zenpacklib.py to address modeler timeouts from attribute-indexed components
3.1.0
Numerous enhancements and bugfixes
3.0.2
Fixes ZEN-18151. HP.wbem.HPWBEMPlugin modeling traceback on tempStatus()
3.0.1
Standardized commonly used code for converting RRD status to formatted string
Standardized most component properties to those common between collection methods (some still outstanding)
Standardized common datasource/datapoint names throughout templates
Simplified customized classes to reduce duplication of function
Removed duplicate property definitions with similar names but identical values
Removed most component properties that should have been performance or status datasources
Standardized unit testing for modeler plugins and class loading
Folded deviceMap modeler plugins into component modeler plugins, removed device map plugins
Added ZenPack class to remove all RRD templates upon ZP uninstall
Changed Fan Speed to display status string (only ILO shows actual speed)
SNMP modeler plugins are now appropriate for use wherever SNMP is supported
Deprecated HPOSHypervisor and HPThermalSubsystem components
Removed COMMAND datasource from HPLogicalDrive (used snmpindex_dct instead)
Added ILO datasource queries for HPChassis, HPProcessor, HPManagementController, HPNetworkInterfaceController, and updated ILODatasource to accommodate
Added "perfID" to ILO HPTemperature components to correct some missing datapoints
Updated migrate methods to remove all templates before re-adding from YAML
Removed "uptime" metric from HPSystemBoard since it duplicates the Device sysUptime datapoint
Added several status indicators to HPManagementController component (SNMP)
Re-based SNMP Device templates on /Server/Linux to ensure consistency
3.0.0
Major rewrite of significant sections of the zenpack to use zenpacklib and remove obvious defects.
1.0.0
Initial release.