Skip to main content

Juniper Devices

ZenPacks.zenoss.JuniperMonitor

The JuniperMonitor ZenPack allows system administrators to monitor their Juniper devices.

Support

This ZenPack is developed and supported by Virtana. Enterprise support is available to Virtana customers with an active subscription or support agreement. ZenPacks are available at delivery.zenoss.com. To request more information about this or any other ZenPack, contact Virtana.

Releases

Version 2.1.1

  • Released on 2014/03/05

  • Compatible with Virtana Service Dynamics 4.1.x, Virtana Service Dynamics 4.2.x, Virtana Service Dynamics 5.x.x

Prerequisites

Prerequisite

Restriction

Product

Zenoss platform 4.x, Zenoss 2.2 or higher

Required ZenPacks

ZenPacks.zenoss.JuniperMonitor

Configuring Juniper Devices to Allow SNMP Queries

Configure the Juniper device to allow SNMP queries from the Virtana platform server, and send SNMP v1 or SNMP v2 traps to the Virtana platform server.

Configuring Virtana platform

All Juniper devices must exist under the /Devices/Network/Juniper device class.

  1. Navigate to the device or device class in the Virtana platform interface.

    • If applying changes to a device class:

      1. Select the class in the devices hierarchy.

      2. Click Details.

      3. Select Configuration Properties.

    • If applying changes to a device:

      1. Click the device in the device list.

      2. Select Configuration Properties.

  2. Edit the appropriate configuration properties for the device or devices.

    Juniper Configuration Properties

    Name

    Description

    zSnmpCommunity

    Consult with your network administrators to determine the SNMP community permitted.

    zSnmpMonitorIgnore

    Set to a value of False.

    zSnmpPort

    Set the SNMP port. The default port is 161.

    zSnmpVer

    Set the SNMP version. Set to a value of v2c.

  3. Click Save to save your changes. You will now be able to start collecting the Juniper device metrics from this device.

  4. Navigate to Graphs and you should see some place holders for graphs. After approximately fifteen minutes you should see the graphs start to become populated with information.

Daemons

Type

Name

Type

Name

Modeler

zenmodeler

Performance Collector