Skip to main content

Update and Install Information

The .upd update bundles contain the files required to complete an upgrade to an existing installation and are available for an Appliance, Virtual Edition.

For complete information on updating IO, refer to Chapter 1 of the Virtana Infrastructure Observability Administrator Guide.

Upgrade Path

You can upgrade to this release directly from IO releases 7.2.3 - 2026.6.1.

Upgrading from other IO releases require assistance from Virtana. Please refer to the documents named Important_READ_before_an_upgrade_to_IO_2026.9.1-GA.pdf and Important_Update_Instructions_for_Firmware_2026.4.1.pdf for complete upgrade path information. These documents are located on Egnyte, Virtana's official software distribution tool.

See applicable information below and further upgrade details in the Virtana Infrastructure Observability Administrator Guide.

New Installs

When doing a new install, it can take up to 45 minutes for all services to start.

Licensing Requirement

Tip

If uploading a new IO License as part of an update, you must reboot the IO Appliance or Virtual Edition after applying the new license. (If you do not reboot, you will see the message, “Error loading dashboard due to metrics and/or licensing issues.”)

Tasks Prior to Updating: Important

The following tasks should be completed before you begin a new installation or an update of IO .

  1. Back up your IO Platform Appliance immediately before performing an update. Backups are not performed as part of the upgrade process.

    IO Restore from Backup is supported for release 2026.9.1.

  2. Remove all hotfixes before installing the IO update.

Warning

Factory reset before upgrade is not advisable, as it can cause issues.

Upgrade Tips

  • If you do a multi-hop update, ensure the update completes and all services are running before starting the next update. To verify that services are running, navigate to Settings > Service Management in IO .

  • After updating to this release, if a backup of a prior release is restored on the same appliance (i.e., appliance with the same UUID) that has been upgraded to this release, then the new license file will be overwritten. You must reapply the updated license after the system comes back up.

  • If you try to log in to IO before the update completes, you get an "unknown error" message.

  • You cannot run a backup until at least 24 hours after the update completes.

Updating When Using Integrations

If you plan to use any of the following integrations and they are not already enabled, enable them first.

The following integrations are included with the IO core package except where noted below. If licensed and already configured, they will be automatically upgraded to the versions listed.

Note

Integration bundles released prior to this IO version are not supported.

IO Integration

Version for This Release

Dell EMC Isilon / PowerScale Integration

5.3.4

Dell EMC VMAX/PowerMax Integration

5.3.0

IBM SVC / IBM Modular Integration

4.3.5

KVM Integration

2.2.7

NetApp Storage Integration

2.5.2

Pure Flash System Integration

5.0.5

Solaris Integration

2.1.9

Linux Integration

3.4.4

Windows Integration

3.2.6

Cisco UCS

4.3.3

Infinidat InfiniBox

3.3.10

Dell EMC XtremIO

3.2.9

Dell EMC PowerStore

1.5.12

Cisco Nexus

2.1.9

Hitachi VSP

2.3.5

Dell EMC Unity

2.2.8

IO Public API

3.2.5

Virtana Cloud Sync

3.2.3

HPE

1.2.6

IP Switch

2.0.4

Dell PowerProtect

1.0.8

RedFish

1.0.2

Objectscale

1.1.0

Hitachi Content Platform (hcp) HCP

1.2.4

Hitachi NAS

1.3.6

Nutanix

2.0.3

VPLEX

1.3.9

For more information about these integrations, see the User Guide and Release Notes for each integration.