Known Issues
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-79924 | Multi metric alarms does not support Email and SNMP notifications. | Email and SNMP notifications for multi-metric changes are not included in this release. | N/A |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-80718 | Incorrect integration version displayed if service is stopped | When an integration is restored from a backup and remains disabled, the displayed version may be incorrect until the integration is enabled. | N/A |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-78179 | VW on Kubernetes Deployment | When a Hardware Probe is added to the Kubernetes appliance, a connection error is displayed. | N/A |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-79158 | NetApp | NetApp E-series is not currently supported by this integration. | N/A |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-78431 | LDAP | Virtana IO does not currently support the use of Domain Local Groups (DLGs) containing nested Global Groups (GGs) for authentication. | N/A |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-76666 | Kubernetes | On Kubernetes (K8s), when the VMware integration is added without enabling ScaleIO, the VMware collection fails and displays an "Internal Communication Error." | To resolve this issue, enable the ScaleIO integration alongside the VMware integration, as VMware is dependent on ScaleIO for proper functionality. |
VW-76699 | Kubernetes | Unable to subscribe to probes | Before configuring the probes, on the UI > Settings > Service Management page, set this property on “Hardware Probe Management Service”: com.vi.probehwproxy.public.ip to point to the HW Proxy Load Balancer IP. Restart vw-probe-hw-proxy pod for the property to take effect. Add the probes and subscribe as usual. |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-75496 | IO | The default disk size of the IO appliance is 1TB, and it can grow up to 1.99TB | Planned for removal. |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-75012 | HyperV Integration | HyperV data collection is not working. | To start discovery using WinRM, set the property "com.vi.hyperv.winRM" to "true". By default, it is false. This Property can be set from Settings > Service Management > Microsoft Hyper-V Integration > Set Properties. |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-59192 | Capacity Auditor | Capacity Auditor does not work for generic storage array entities because the storage array entity does not have capacity information. | None |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-73521 | Backup and Restore will not work. | If SSH access is disabled on the Appliance due to Security reasons, Backup or Restore will not work. | Enable the SSH access and then perform Backup or Restore. |
VW-71781 | Backup schedule not executed as expected. | Backup scheduled to coincide with the daylight saving time "jump ahead" will be skipped, as that hour is skipped. | Change the backup day and/or time to not coincide with daylight saving time change for your location, or contact Virtana support as necessary. |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-56814 | Hardware, SFP transceivers | Valid SFP transceivers can sometimes be identified as invalid by the alerting system. | Ignore the false alerts. |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-76106 | Slack Integration | Virtana is aware that Slack has deprecated their Incoming Webhooks method for posting messages to their platform and that capability will be removed in an as yet to be determined future release. Virtana is working on an updated solution that will leverage current Slack APIs. | None |
VW-57839 | NetFlow | The "Network Service" template variable filter in the 'Template - NetFlow Investigation' report always results in an empty report. | Modify the filters for the affected charts to remove the "Use entities related to this Network Service" filter option and add a "Calculate this chart using data from Network Service" option. |
VW-59515 | ServiceNow, Notifications | When a ServiceNow case is created in IO Infrastructure Observability , and the incident is closed from ServiceNow, the designated user always receives two notification emails indicating that the case was closed. | None |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-73375 | All charts | Cisco Nexus: The values for "CPU Core" metrics may not exactly match between Telemetry and NxAPI collection. | None. |
VW-70279 | Line charts | When multiple metrics are chosen and share a different set of unit types (e.g., two GB metrics and two MB/s metrics), the metrics will link only the primary axis' unit type and the other sets will not be linked. | None. |
VW-59496 | Freeform Chart | Upgraded Reports that include a freeform chart do not produce a Scheduled Report/Snapshot email attachment. | The freeform chart needs to be refreshed. Do one of the following: 1) For a single chart, open the chart configuration and click OK, wait for the loading icon on the chart to finish, and then save the report. 2) If you have multiple Freeform Charts on the report, you can refresh all charts at the same time by doing a normal PDF export and then saving the report. |
VW-59191 | Inventory Table Chart | The Inventory Table Chart does not currently export the severity icons. | None |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-47556 | User Groups | User Groups and users within those groups do not have properly formatted display names when added to Access Levels. | None |
Defect | Impact | Description | Workaround |
|---|---|---|---|
VW-78152 | Brocade | In the inventory list screen for “Switch Port”, you cannot sort the properties for newly added Brocade-specific properties. | None |