The following table contains descriptions of the integration's preconfigured alarms and their default settings.
Name | Description | Settings | |||
Tier 0 PowerMax Cache Write Pending | Monitors a PowerMax storage array for high cache write pending conditions. Triggers when the percentage of cache that is write-pending exceeds 45% for 1 minute. |
| |||
Tier 0 PowerMax Capacity Usage | Monitors a PowerMax storage array's percentage of used capacity. Triggers when that percentage exceeds 90% for more than 30 minutes. |
| |||
Tier 0 PowerMax Storage Group Read Response Time | Monitors a PowerMax Storage Groups's average read response time. Triggers when that average exceeds 30 ms for more than 15 minutes. |
| |||
Tier 0 PowerMax Storage Group Write Response Time | Monitors a PowerMax Storage Groups's average write response time. Triggers when that average exceeds 20 ms for more than 15 minutes. |
| |||
Tier 1 PowerMax Cache Write Pending | Monitors a PowerMax storage array for high cache write pending conditions. Triggers when the percentage of cache that is write-pending exceeds 45% for 5 minutes. |
| |||
Tier 1 PowerMax Storage Group Read Response Time | Monitors a PowerMax Storage Groups's average read response time. Triggers when that average exceeds 50 ms for more than 15 minutes. |
| |||
Tier 1 PowerMax Storage Group Write Response Time | Monitors a PowerMax Storage Groups's average write response time. Triggers when that average exceeds 30 ms for more than 15 minutes. |
| |||
Tier 1 PowerMax Subscribed Capacity Usage | Monitors a PowerMax storage array's percentage of subscribed capacity. Triggers when that percentage exceeds 95% for more than 60 minutes. |
|
Alarm Rule Name | Description | Settings |
---|---|---|
Tier 0 PowerMax Cache Write Pending | Monitors a PowerMax storage array for high cache write pending conditions. Triggers when the percentage of cache that is write‐pending exceeds 45% for 1 minute. | Threshold: 45.0 % Duration: 1 minutes Severity: Critical |
Tier 0 PowerMax Storage Group Read Response Times | Monitors a PowerMax Storage Groups's average read response time. Triggers when that average exceeds 30 ms for more than 15 minutes. | Threshold: 30.0 ms Duration: 15 minutes Severity: Critical |
Tier 0 PowerMax Storage Group Write Response Times | Monitors a PowerMax Storage Groups'saverage write response time. Triggers when that average exceeds 20 ms for more than 15 minutes. | Threshold: 20.0 ms Duration: 15 minutes Severity: Critical |
Tier 0 PowerMax Subscribed Capacity Usage | Monitors a PowerMax storage array's percentage of subscribed capacity. Triggers when that percentage exceeds 90% for more than 30 minutes. | Threshold: 90.0 % Duration: 30 minutes Severity: Critical |
Tier 1 PowerMax Cache Write Pending | Monitors a PowerMax storage array for high cache write pending conditions. Triggers when the percentage of cache that is write‐pending exceeds 45% for 5 minutes. | Threshold: 45.0 % Duration: 5 minutes Severity: Critical |
Tier 1 PowerMax Storage Group Read Response Times | Monitors a PowerMax Storage Groups's average read response time. Triggers when that average exceeds 50 ms for more than 15 minutes. | Threshold: 50.0 ms Duration: 15 minutes Severity: Critical |
Tier 1 PowerMax Storage Group Write Response Times | Monitors a PowerMax Storage Groups's average write response time. Triggers when that average exceeds 30 ms for more than 15 minutes. | Threshold: 30.0 ms Duration: 15 minutes Severity: Critical |
Tier 1 PowerMax Subscribed Capacity Usage | Monitors a PowerMax storage array's percentage of subscribed capacity. Triggers when that percentage exceeds 95% for more than 60 minutes. | Threshold: 95.0 % Duration: 60 minutes Severity: Critical |